ANNEX IV

Table I A

Containment and other protective measures for laboratory activities

Specifications
Containment levels
1
2
3
4

1

Laboratory suite: isolation (1)

Not required

Not required

Required

Required

2

Laboratory: sealable for fumigation

Not required

Not required

Required

Required

Equipment

3

Surfaces resistant to water, acids, alkalis, solvents, disinfectants, decontamination agents and easy to clean

Required (bench)

Required (bench)

Required (bench, floor)

Required (bench, floor, ceiling, walls)

4

Entry to lab via airlock (2)

Not required

Not required

Optional

Required

5

Negative pressure relative to the pressure of the immediate environment

Not required

Not required

Required except for (3)

Required

6

Extract and input air from the laboratory should be HEPA-filtered

Not required

Not required

Required (HEPA) (4) - extract air except for (3)

Required (HEPA) (5) - input and extract air

7

Microbiological safety post

Not required

Optional

Required

Required

8

Autoclave

On site

In the building

En suite (6)

In lab = double-ended

System of work

9

Restricted access

Not required

Required

Required

Required

10

Biohazard sign on the door

Not required

Required

Required

Required

11

Specific measures to control aerosol dissemination

Not required

Required
minimise

Required
prevent

Required
prevent

13

Shower

Not required

Not required

Optional

Required

14

Protective clothing

Suitable protective clothing

Suitable protective clothing and (optional) footwear

Suitable protective clothing

Complete change of clothing and footwear before entry and exit

15

Gloves

Not required

Optional

Required

Required

18

Efficient vector control (e.g. for rodents and insects)

Optional

Required

Required

Required

Waste

19

Inactivation of GMMs in effluent from hand-washing sinks or drains and showers and similar effluents

Not required

Not required

Optional

Required

20

Inactivation of GMMs in contaminated material and waste

Optional

Required

Required

Required

Other measures

21

Laboratory to contain its own equipment

Not required

Not required

Optional

Required

23

An observation window or alternative is to be present so that occupants can be seen

Optional

Optional

Optional

Required

(1) Isolation = the laboratory is separated from other areas in the same building or is in a separated building
(2) Airlock = entry must be through an airlock which is a chamber isolated from the laboratory. The clean side of the airlock must be separated from the restricted side by changing or showering facilities and preferably by interlocking doors.
(3) Activities where transmission does not occur via airborne route.
(4) HEPA = High efficiency particulate air.
(5) Where viruses which are not retained by HEPA filters are used, extra requirement will be necessary for extract air.
(6) With validated procedure, allowing the safe transfer of material into an autoclave outside the lab, and providing an equivalent level of protection.


BELGIAN BIOSAFETY SERVER : Directive 98/81/EC
[Annex IV : Principles - Table I A - Table I B - Table I C - Table II]
[Contents] [Preamble] [Articles] [Annex I] [Annex II] [Annex III] [Annex V]